NORSOK Z-015 Type U07 - Well service equipment

免费
老杨树 2024-11-30 11 252.24KB 2 页 免费
侵权投诉
Telephone:
Date approval received:
Ref. Status Remarks
Z-015 supplier
1.1. 4.6
1,2 4.4.1
1,3 4.4.1
1,9 4.4.8
2,1 4.4.3
2,2 4.4.2
2,4 4.4.2
2,7 4.4.2
3,1 4.4.6.1
3,2 37107
3,3 4.4.6.3
3,4 4.5.1
3,5 4.5.1
3,6 4.4.6.2
4,1 4,7
4,3 4,7
4,4 4,7
4,5 4.4.3
Control
point
Supplier:
Contact person contractor/telephone:
Name:
Contact person/requisitioner in the company:
Company/installation container intended for:
NORSOK Z-015 CHECKLIST
Equipment type :
Well equip., wireline, logging, coiltubing
ID no.:
Approved for location in zone:
Zone 1 □ , Zone 2 □, Non-hazardous area □
Insulation resistance - megger
Earthing (NB bonding of structure)
All external installation Ex-proof
Person in the company responsible for prior approval, see 4.8.3:
Status:
Receiving
control
(company)
OK=Approved, NA=Not Applicable, NC=Not Checked,
D=Defective or missing
1. MECHANICAL
Signs tagging/labelling
Annual inspection (lifting equipment, cert.)
Mech. Cond. (lifting eyes/points, structure)
Noise measurement carried out (supplier)
2. FIRE, GAS AND SAFETY
Gas detector in air inlet
All internal installation Ex-proof
Emergency lighting
Fire/smoke detector
Extinguisher
Romslukkingsanlegg
3. ELECTRICAL
Cables, glands, equipment etc.
4. HOOK-UP TO INSTALLATION
PA with plug
Alarm signal to control room with plug
Shutdown (ESD) from CCR (for battery system etc.)
Power supply (voltage, freq., plugs)
Printed: 03.12.2012 at 15:46
NORSOK Z-015 Rev. 4 - September 2012 Page: 1 of 2
5,1 4.4.8
5,2 4.3.1
5,3 4.3.1
5,4 4.3.1
5,5 4.3.1
5,6 4.3.1
5,7 4.3.1
5,8 4.3.1
5,9 4.3.1
5,1 4.3.1
5,11 4.3.1
5,15 4.3.6
6,1 4.8
6,2 4.8
6,3 4.8
6,4 4.8
6,5 4.8
6,6 4.8
Date: Date:
Signature Signature Signature
Name in capitals Name in capitals
0
Competent person for lifting gir/mechanical
devices
Electrician
Receiving control
Date:
Name in capitals
Supplier
Supplier
Company
Other technical doc. (drawings, data.)
"Rig saver" in combustion air inlet
Shutdown if overspeed
Diesel engine approved for zone 2
Gas detector in combustion air inlet
Flame arrester in exhaust pipe
Spark arrester in exhaust pipe
Maintenance journal
User manual
Check of limit switches
6. DOCUMENTATION
Lifting certificate
Certificate for equip.with special requ.
5. EQUIPMENT
Maintenance programme
Manual emergency stop
Manual shutdown of diesel supply
Drip trays
Shutdown if loss of oil pressure
Shutdown if high cooling water temperature
Printed: 03.12.2012 at 15:46
NORSOK Z-015 Rev. 4 - September 2012 Page: 2 of 2
摘要:

This page provides a comprehensive overview of the NORSOK Z-015 Type U07 standard, specifically focused on the design, manufacturing, and certification requirements for well service equipment used in the Norwegian continental shelf oil and gas indust

展开>> 收起<<
NORSOK Z-015 Type U07 - Well service equipment.pdf

共2页,预览2页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:老杨树 分类:国际标准 价格:免费 属性:2 页 大小:252.24KB 格式:PDF 时间:2024-11-30

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 2
客服
关注