ANSI EIA-364-20C-2004

VIP免费
可爱滴龅牙 2025-10-15 66 104.96KB 11 页 14星币
侵权投诉
EIA
STANDARD
TP-20C
WITHSTANDING VOLTAGE TEST
PROCEDURE FOR ELECTRICAL
CONNECTORS, SOCKETS AND
COAXIAL CONTACTS
EIA-364-20C
(Revision of EIA-364-20B)
June 2004
ELECTRONIC COMPONENTS, ASSEMBLIES & MATERIALS
ASSOCIATION
THE ELECTRONIC COMPONENTS SECTOR OF THE ELECTRONIC INDUSTRIES ALLIANCE
ANSI/EIA-364-20C
Approved: June 3, 2004
EIA-
364-
20C
NOTICE
EIA Engineering Standards and Publications are designed to serve the public interest
through eliminating misunderstandings between manufacturers and purchasers,
facilitating interchangeability and improvement of products, and assisting the purchaser
in selecting and obtaining with minimum delay the proper product for his particular
need. Existence of such Standards and Publications shall not in any respect preclude
any member or nonmember of EIA from manufacturing or selling products not
conforming to such Standards and Publications, nor shall the existence of such
Standards and Publications preclude their voluntary use by those other than EIA
members, whether the standard is to be used either domestically or internationally.
Standards and Publications are adopted by EIA in accordance with the American
National Standards Institute (ANSI) patent policy. By such action, EIA does not
assume any liability to any patent owner, nor does it assume any obligation whatever to
parties adopting the Standard or Publication.
This standard is based upon the major technical content of International
Electrotechnical Commission standard 512-2, test 4a, voltage proof, 1985. It conforms
in all essential respects this IEC standard.
This Standard does not purport to address all safety problems associated with its use or
all applicable regulatory requirements. It is the responsibility of the user of this
Standard to establish appropriate safety and health practices and to determine the
applicability of regulatory limitations before its use.
Published by
©ELECTRONIC INDUSTRIES ALLIANCE 2004
Engineering Department
2500 Wilson Boulevard
Arlington, VA 22201
i
CONTENTS
Clause Page
1 Introduction ............................................................................................................... 1
1.1 Scope ......................................................................................................................... 1
1.2 Object ........................................................................................................................ 1
2 Test resources ............................................................................................................ 1
2.1 Equipment ................................................................................................................. 1
3 Test specimen ............................................................................................................ 2
3.1 Description ................................................................................................................ 2
3.2 Preparation ................................................................................................................ 2
4 Test procedure ........................................................................................................... 3
4.1 Points of application ................................................................................................. 3
4.2 Barometric pressure .................................................................................................. 3
4.3 Test voltage ............................................................................................................... 4
4.4 Rate of application ..................................................................................................... 4
4.5 Duration of application ............................................................................................. 4
4.6 Examination and measurement of specimen ............................................................. 5
5 Details to be specified ............................................................................................... 5
6 Test documentation ................................................................................................... 6
Table
1 Test conditions .......................................................................................................... 4
Annex
A Normative ................................................................................................................. A-1
B Informative ................................................................................................................ B-1
摘要:

ANSI EIA-364-20C-2004 是美国国家标准学会(ANSI)与电子工业联盟(EIA)联合发布的电连接器及插座温升测试标准,属于 EIA-364 系列规范之一。该标准详细规定了在额定电流条件下测量电连接器接触界面温升的试验方法,包括测试样品的安装要求、环境温度控制、电流施加时长、热电偶布置位置及数据记录步骤。它适用于各类电连接器、端子及互连元件,旨在确保连接器在长期通电工况下的热性能满足可靠性要求,为产品设计、质量验证及合规性评估提供统一依据。标准版本中的“C”表示第三次修订,替代了

展开>> 收起<<
ANSI EIA-364-20C-2004.pdf

共11页,预览3页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:可爱滴龅牙 分类:国际标准 价格:14星币 属性:11 页 大小:104.96KB 格式:PDF 时间:2025-10-15

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 11
客服
关注