CLSI H47-A3-2023 单阶段凝血酶原时间 (PT) 检测和活化部分凝血酶原时间 (APTT) 检测

VIP专享
可爱滴龅牙 2026-07-24 21 7.09MB 66 页 35星币
侵权投诉
H47
One-Stage Prothrombin Time (PT) Test and
Activated Partial Thromboplastin Time (APTT)
Test
This document provides guidelines for performing the PT and
APTT tests in the clinical laboratory, for reporting results, and for
identifying sources of error.
A guideline for global application developed through the Clinical and Laboratory Standards Institute consensus process.
3rd Edition
Clinical and Laboratory Standards Institute
Setting the standard for quality in medical laboratory testing around the world.
The Clinical and Laboratory Standards Institute (CLSI) is a not-for-prot membership organization that brings
together the varied perspectives and expertise of the worldwide laboratory community for the advancement of a
common cause: to foster excellence in laboratory medicine by developing and implementing medical laboratory
standards and guidelines that help laboratories fulll their responsibilities with efficiency, effectiveness, and global
applicability.
Consensus Process
Consensusthe substantial agreement by materially affected, competent, and interested parties—is core to the
development of all CLSI documents. It does not always connote unanimous agreement but does mean that the
participants in the development of a consensus document have considered and resolved all relevant objections
and accept the resulting agreement.
Commenting on Documents
CLSI documents undergo periodic evaluation and modication to keep pace with advances in technologies,
procedures, methods, and protocols affecting the laboratory or health care.
CLSI’s consensus process depends on experts who volunteer to serve as contributing authors and/or as participants
in the reviewing and commenting process. At the end of each comment period, the committee that developed
the document is obligated to review all comments, respond in writing to all substantive comments, and revise the
draft document as appropriate.
Comments on published CLSI documents are equally essential and may be submitted by anyone, at any time, on
any document. All comments are managed according to the consensus process by a committee of experts.
Appeal Process
When it is believed that an objection has not been adequately considered and responded to, the process for
appeal, documented in the CLSI Standards Development Policies and Processes, is followed.
All comments and responses submitted on draft and published documents are retained on le at CLSI and are
available upon request.
Get Involved—Volunteer!
Do you use CLSI documents in your workplace? Do you see room for improvement? Would you like to get
involved in the revision process? Or maybe you see a need to develop a new document for an emerging
technology? CLSI wants to hear from you. We are always looking for volunteers. By donating your time and talents
to improve the standards that affect your own work, you will play an active role in improving public health across
the globe.
For additional information on committee participation or to submit comments, contact CLSI.
Clinical and Laboratory Standards Institute
P: +1.610.688.0100
F: +1.610.688.0700
www.clsi.org
The Clinical and Laboratory Standards Institute consensus process, which is the mechanism for moving a document through two
or more levels of review by the health care community, is an ongoing process. Users should expect revised editions of any given
document. Because rapid changes in technology may affect the procedures, methods, and protocols in a standard or guideline,
users should replace outdated editions with the current editions of CLSI documents. Current editions are listed in the CLSI catalog
and posted on our website at www.clsi.org.
If you or your organization is not a member and would like to become one, or to request a copy of the catalog, contact us at:
P: +1.610.688.0100 F: +1.610.688.0700 E: customerservice@clsi.org W: www.clsi.org
H47-Ed3
March 2023
Replaces H47-A2
One-Stage Prothrombin Time (PT) Test and Activated Partial
Thromboplastin Time (APTT) Test
Donna D. Castellone, MS, MASCP, MT(ASCP)SH
Karen A. Moser, MD
Elizabeth M. Van Cott, MD
Richard A. Marlar, PhD
Janet Cook, MT(ASCP)
Marilyn Johnston, ART
Stephen Kitchen, FIBMS, PhD
Samuel J. Machin, MB, ChB, FRCPath
Diane Shafer, MT(ASCP)
Laura Worfolk, PhD
Abstract
Clinical and Laboratory Standards Institute document H47One-Stage Prothrombin Time (PT) Test and Activated Partial
Thromboplastin Time (APTT) Test describes the principles and procedures necessary for the routine performance of the
PT and APTT by conventional techniques using citrated plasma. Each of the two tests measures the time for a brin clot
to develop in test plasma after activation. The chemical reactions are complex and, characteristically, results are affected
by preexamination (preanalytical) and examination (analytical) variables. The PT and APTT are important screening tests
used in laboratory evaluation of patients suspected to have disorders of blood coagulation, including the presence of
circulating coagulation inhibitors. The PT measures the extrinsic or tissue factor pathway of the coagulation system and
is used to monitor vitamin K antagonist therapy. The APTT measures the intrinsic coagulation pathway and is used in
monitoring heparin therapy, as well as parenteral direct thrombin inhibitor anticoagulant therapy such as argatroban
and lepirudin. The objective of this guideline is to improve test reproducibility through standardization of technique and
ensure clinical relevance by setting test performance goals. The document also highlights the international effort for
standardization of the PT through the use of the international normalized ratio.
Clinical and Laboratory Standards Institute (CLSI). One-Stage Prothrombin Time (PT) Test and Activated Partial
Thromboplastin Time (APTT) Test. 3rd ed. CLSI guideline H47 (ISBN 978-1-68440-172-7 [Print]; ISBN 978-1-68440-173-4
[Electronic]). Clinical and Laboratory Standards Institute, USA, 2023.

标签: #CLSI #检测

摘要:

该文档为 CLSI H47-A3-2023 标准规范,主要涵盖单阶段凝血酶原时间 (PT) 和活化部分凝血酶原时间 (APTT) 检测的标准化流程与最新技术要求。作为临床实验室凝血功能检测的核心参考文件,该标准详细规定了样本采集、试剂选择、仪器校准、质控措施及结果解读的规范化操作,旨在提升凝血检测的准确性与一致性。适用于血液学实验室、临床检验科及体外诊断行业从业者,帮助优化凝血功能评估流程,降低检测变异,确保患者诊疗安全。通过学习该标准,实验室可更好地满足国际质量管理要求,实现 PT 与 APT

展开>> 收起<<
CLSI H47-A3-2023 单阶段凝血酶原时间 (PT) 检测和活化部分凝血酶原时间 (APTT) 检测.pdf

共66页,预览3页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:可爱滴龅牙 分类:国外协会 价格:35星币 属性:66 页 大小:7.09MB 格式:PDF 时间:2026-07-24

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 66
客服
关注