沙特阿美公司材料系统规范 15-SAMSS-502 5kV至35kV中压电力电缆 2020 Medium Voltage Power Cable 5 kV through 35 kV

VIP专享
标准之家 2026-09-13 6 768.87KB 15 页 26星币
侵权投诉
Previous Issue: 01 January 2018 Next Planned Update: 20 November 2022
Revised paragraphs are indicated in the right margin Page 1 of 15
Contact: Bugshan, Jamal A. (bugshaja) on phone +966-13-8809650
©Saudi Aramco 2020. All rights reserved.
Saudi Aramco: Company General Use
Materials System Specification
15-SAMSS-502 20 May 2020
Medium Voltage Power Cable 5 kV through 35 kV
Document Responsibility: Electrical Systems Designs and Automation Standards
Committee
Contents
1 Scope ..................................................................... 2
2 Conflicts and Deviations ......................................... 2
3 References ............................................................. 2
4 Field Experience ..................................................... 3
5 General .................................................................. 3
6 Medium Voltage Power Cable per IEC 60502-2 ..... 4
7 Medium Voltage Power Cable per AEIC CS8 ........ 6
8 Other Requirements ............................................... 8
Revision Summary ...................................................... 10
Data Sheets ............................................................... 11
Document Responsibility: Electrical Systems Designs and Automation Standards Committee 15-SAMSS-502
Issue Date: 20 May 2020
Next Planned Update: 20 November 2022 Medium Voltage Power Cable 5 kV through 35 kV
Saudi Aramco: Company General Use
Page 2 of 15
Saudi Aramco: Company General Use
1 Scope
This specification defines the mandatory requirements for dielectric insulated power
cables with rated voltages from 5 kV through 35 kV, 50 or 60 Hz. Submarine,
submersible pump (down hole), portable, and motor lead cables are outside the scope
of this specification.
2 Conflicts and Deviations
2.1 Any conflicts between this document and other applicable Mandatory Saudi
Aramco Engineering Requirements (MSAERs) shall be addressed to the
EK&RD Coordinator.
2.2 Any deviation from the requirements herein shall follow internal company
procedure SAEP-302.
2.3 The designation “Commentary” is used to label a sub-paragraph that contains
comments that are explanatory or advisory. These comments are not mandatory,
except to the extent that they explain mandatory requirements contained in this
SAMSS.
3 References
The following is a summary of all the documents which have been mentioned within
this specification. The specific part(s) of these documents which are applicable have
been identified throughout this specification.
3.1 Saudi Aramco References
Saudi Aramco Engineering Procedure
SAEP-302 Waiver of a Mandatory Saudi Aramco Engineering
Requirement
Saudi Aramco Inspection Requirements
Form 175-150200 Medium Voltage Power Cable 5 kV through 35 kV
3.2 Industry Codes and Standards
American Society for Testing and Materials
ASTM B8 Concentric-Lay-Stranded Copper Conductors,
Hard, Medium Hard, or Soft
ASTM B496 Compact Round Concentric-Lay-Stranded Copper
Conductors
Document Responsibility: Electrical Systems Designs and Automation Standards Committee 15-SAMSS-502
Issue Date: 20 May 2020
Next Planned Update: 20 November 2022 Medium Voltage Power Cable 5 kV through 35 kV
Saudi Aramco: Company General Use
Page 3 of 15
Saudi Aramco: Company General Use
Association of Edison Illuminating Companies
AEIC CS8 Specification for Extruded Dielectric, Shielded
Power Cables Rated 5 through 46 kV
Insulated Cable Engineers Association
ICEA S-94-649 Concentric Neutral Cables Rated 5,000 - 46,000 Volts
ICEA S-97-682 Utility Shielded Power Cables Rated 5,000 - 46,000
Volts
International Electrotechnical Commission
IEC 60038 IEC Standard Voltages
IEC 60228 Conductors of Insulated Cables
IEC 60332-3-23 Test for Vertical Flame Spread of Vertically-
Mounted Bunched Wires or Cables - Category B
IEC 60502-2 Power Cables with Extruded Insulation and their
Accessories for Rated Voltages from 1 kV
(Um = 1,2 kV) up to 30 kV (Um = 36 kV)
Underwriters Laboratories
UL 1072 Standard for Medium Voltage Power Cable
4 Field Experience
Designs, materials and methods of construction used in cable shall have a minimum of
6 years of verifiable, proven field experience. (Local manufacturer is exempted).
Vendor shall supply a User List indicating User company name, installation site, date of
installation, and characteristics similar to cable quoted.
5 General
Medium Voltage Power Cable shall be manufactured and tested in accordance with
International Electrotechnical Commission (IEC) 60502-2, or in accordance with
Association of Edison Illuminating Companies (AEIC) CS8, as specified in the
purchase order or in the Saudi Aramco Materials System Specification (SAMSS)
description, with additional requirements as outlined below:
5.1 Cable manufactured to IEC 60502-2 shall meet the requirements of Sections 6
and 8 below.
5.2 Cable manufactured to AEIC CS8 shall meet the requirements of Sections 7 and
8 below.

标签: #MS #材料 #沙特

摘要:

本页面围绕沙特阿美公司材料系统规范 15-SAMSS-502 5kV至35kV中压电力电缆 2020 Medium Voltage Power Cable 5 kV through 35 kV 展开,介绍该2020版标准在沙特阿美项目中对5 kV至35 kV中压电力电缆的材料、结构、制造、检验、试验、标识、包装及交付验收等要求。适用于工程师、采购人员、供应商、承包商查询15-SAMSS-502规范、中压电力电缆技术条件、沙特阿美合规要求及项目选型依据,便于招标采购、质量控制与文档管理。

展开>> 收起<<
沙特阿美公司材料系统规范 15-SAMSS-502 5kV至35kV中压电力电缆 2020 Medium Voltage Power Cable 5 kV through 35 kV.pdf

共15页,预览3页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:标准之家 分类:国际标准 价格:26星币 属性:15 页 大小:768.87KB 格式:PDF 时间:2026-09-13

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 15
客服
关注