沙特阿美公司材料系统规范 34-SAMSS-634 现场ZV控制系统 2020 Local ZV Control Systems

VIP专免
标准之家 2026-09-13 6 271.02KB 7 页 25星币
侵权投诉
Previous Issue: 12 Novmber 2017 Next Planned Update: 12 November 2022
Page 1 of 7
Contact: Hamad, Fahad M. (hamafm0a) on phone +966-13-8801340
©Saudi Aramco 2017. All rights reserved.
Saudi Aramco: Company General Use
Materials System Specification
34-SAMSS-634 19 January 2020
Local ZV Control Systems
Document Responsibility: Instrumentation Standards Committee
Contents
1 Scope ................................................................ 2
2 Conflicts and Deviations ................................... 2
3 References ........................................................ 2
4 Terminology ...................................................... 3
5 Environmental Conditions ................................. 4
6 General Requirements ...................................... 5
7 ZV Partial Stroke Testing Systems ................... 6
8 Inspection.......................................................... 7
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-634
Issue Date: 19 January 2020
Next Planned Update: 12 November 2022 Local ZV Control Systems
Page 2 of 7
Saudi Aramco: Company General Use
1 Scope
This specification covers the Saudi Aramco requirements of PST for power operated
Emergency Isolation Valve (ZV). The ZV valve assembly provides local control and
testing functionality for valve actuators. Functional requirements are clarified including
the partial stroke feature provided for on-line testing of ZV's. Partial Stroke Testing
(PST) system is not part of the Safety Instrumented System (SIS).
Alternative designs not covered by this specification shall only be used when pre-
approved by the Manager, Process and Control Systems Department.
2 Conflicts and Deviations
Any conflicts between this document and other applicable Mandatory Saudi Aramco
Engineering Requirements (MSAERs) shall be addressed to the EK&RD Coordinator.
Any deviation from the requirements herein shall follow internal company procedure
SAEP-302.
3 References
The following Supplementary Specifications are referenced by and form a part of this
specification.
3.1 Saudi Aramco References
Saudi Aramco Engineering Procedure
SAEP-302 Instructions for Obtaining a Waiver of a Mandatory
Saudi Aramco Engineering Requirement
Saudi Aramco Inspection Requirements
Form 175-343100 Instrument Control Cabinets - Outdoor
Saudi Aramco Forms and Data Sheets
Form SA-8020-634 Local ZV Controls
3.2 Industry Codes and Standards
The cabinet shall be designed and fabricated in conformance with the latest
requirements of the following:
The International Society for Measurement and Control - ISA
ISA RP60.6 Nameplates, Labels, and Tags for Control Centers
Document Responsibility: Instrumentation Standards Committee 34-SAMSS-634
Issue Date: 19 January 2020
Next Planned Update: 12 November 2022 Local ZV Control Systems
Page 3 of 7
Saudi Aramco: Company General Use
National Electrical Manufacturers Association
NEMA 250 Enclosures for Electrical Equipment (1,000 Volts
Maximum) (not in the body of the document)
NEMA ICS 6 Enclosures for Industrial Controls and Systems (not
in the body of the document)
International Electrotechnical Commission (IEC)
IEC 60079 Series Explosive Atmosphere Standards
4 Terminology
4.1 Acronyms
DCS: Distributed Control System
LCP: Local Control Panel
SIS (or ESD): Safety Instrumented System
PST: Partial Stroke Testing
UPS: Uninterruptable Power Supply
4.2 Definitions
Distributed Control System (DCS): A process control system that is composed
of distinct modules. These modules may be physically and functionally
distributed over the plant area. The distributed control system contains all the
modules and associated software required to accomplish the regulatory control
and monitoring of a process plant, excluding field instruments, remote terminal
units, auxiliary control systems, and plant information systems.
Emergency Shutdown System (ESD): A system composed of sensors, logic
solvers, and final control elements for the purpose of taking the process, or
specific equipment in the process to a safe-state when predetermined conditions
are violated or when an operator initiates a shutdown. The system is designed to
isolate, de-energize, shutdown or de-pressure equipment in a process unit.
Another term commonly used throughout the hydrocarbon and petrochemical
industry is a Safety Instrumented System (SIS).
Partial Stroke Testing (PST): It is a way to verify emergency isolation valve
performance when functional testing is required while the emergency isolation
valve is on-line. Partial Stroke testing is not intended to take the place of full-
stroke emergency isolation valve functional tests. Rather, partial stroke
testing should be performed to meet the required functional test interval

标签: #MS #材料 #沙特

摘要:

本文件为沙特阿美公司材料系统规范 34-SAMSS-634《现场ZV控制系统》2020版(Local ZV Control Systems),规定了现场ZV控制系统的设计、选型、材料、制造、检验、测试、标识、包装、运输及交付要求,适用于沙特阿美油气、炼化及工业设施项目的合规采购、工程设计和现场应用。该规范可帮助承包商、供应商、设计院、检验和运维人员准确理解沙特阿美技术标准,确保ZV控制系统在安全性、可靠性、可追溯性与现场适应性方面满足项目要求,并便于技术澄清、质量控制和文件审查。关键词覆盖沙特阿