Tentative Interim Amendment
NFPA® 1906
Standard for Wildland Fire Apparatus
2016 Edition
Reference: 2.3.8, 14.1.1, 14.4, A.14.4, A.14.4.3.4, A.14.1.1(new), and E.1.2.4
TIA 16-3
(SC 17-8-29 / TIA Log #1267)
Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the
National Fire Protection Association has issued the following Tentative Interim Amendment to NFPA
1906, Standard for Wildland Fire Apparatus, 2016 edition. The TIA was processed by the Technical
Committee on Fire Department Apparatus, and was issued by the Standards Council on August 15, 2017,
with an effective date of September 4, 2017.
A Tentative Interim Amendment is tentative because it has not been processed through the entire
standards-making procedures. It is interim because it is effective only between editions of the standard. A
TIA automatically becomes a public input of the proponent for the next edition of the standard; as such, it
then is subject to all of the procedures of the standards-making process.
1. Delete an entry in 2.3.8 to read as follows:
2.3.8 SAE Publications. Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale,
PA 15096-0001
SAE J1194, Rollover Protective Structures (ROPS) for Wheeled Agriculture Tractors, 2009.
2. Revise 14.1.1 to read as follows:
14.1.1* Each crew riding position shall be within a fully enclosed personnel area except as provided in
Section 14.4.
3. Delete section 14.4 through 14.4.3.6 and associated Annexes A.14.4* and A.14.4.3.4 as shown:
14.4* On-Board Pump-and-Roll Fire- Fighting Position.
14.4.1 If an on-board pump-and-roll fire fighting position as described in this section is provided it
shall be on a wildland fire apparatus with a GVWR of no more than 19,500 lbs.
14.4.2 If an on-board pump-and-roll fire fighting position is provided, it shall include the following:
(1) A seat with an approved Type 1 seat belt for each fire- fighting position
(2) Controls required by the operator within reach without removing the seat belt
(3) A means of communication with the driver
(4) One safety sign warning of the hazards of this riding position that is substantially similar to
FAMA44, which warns of riding safety procedures, and the maximum speed of 10 mph visible
from the pump-and-roll fire-fighting position
(5) Safety sign FAMA45, which warns of driving safety procedures, and the maximum speed of 10
mph visible from the driver’s position or visible to the driver while entering the cab
14.4.3 If the seating position is located outside the cab, it shall meet requirements in
14.4.3.1 through 14.4.3.6.
14.4.3.1 The seating position shall be located behind the cab and ahead of the rear axle.
14.4.3.2 A protective structure shall be provided in compliance with the side impact and
crush criteria from SAE J1194,Rollover Protective Structures (ROPS) for Wheeled Agricultural
Tractors.
14.4.3.3 The protective structure shall be designed to allow exit out of either side of the vehicle.
14.4.3.4* The protective structure shall include a perforated plate or mesh with openings no larger than
1.5 in. (3.8 cm) × 1.5 in. (3.8 cm) or other solid guard to protect from brush hazards at the front, the
back, and the roof.
14.4.3.5 A door or gate with a latching mechanism shall be provided on each side of the vehicle
designed to allow exit out of either side of the vehicle.
14.4.3.5.1 The door or gate shall be designed to prevent outward swing even in the event of failure of
the latching mechanism.
14.4.3.5.2 The door or gate shall be at least 48 in. (1200 mm) high from the walking surface below the
firefighter's feet.
14.4.3.5.3 The door or gate shall be constructed so there are no horizontal or vertical openings below
the 48 in. (1200 mm) minimum height greater than 24 in. (610 mm) in either direction.
14.4.3.6 Equipment located within the seating enclosure position protective structure shall meet the
requirements of 14.1.10
A.14.4 Typically, while engaged in fire-fighting operations on structural fires, apparatus are positioned
in a safe location, and hose is extended as necessary to discharge water or suppressants on the
combustible material.
In wildland fire suppression, mobile attack is often utilized in addition to stationary pumping. In
mobile attack, sometimes referred to as pump-and-roll, water is discharged from the apparatus while
the vehicle is in motion. Pump-and-roll operations are inherently more dangerous than stationary
pumping because the apparatus and personnel are in close proximity to the fire combined with the
additional exposure to hazards caused by a vehicle in motion. The personnel and/or apparatus could be
subject to injury or damage due to accidental impact, rollover, and/or environmental hazards, including
burn over.
To mitigate the increased risk inherent with pump-and-roll operations, the following tactics are
recommended:
(1) Driver is located inside the apparatus in a seated, belted position within the enclosed cab. Fire
fighter(s) located outside the cab, walking alongside the apparatus, in clear view of the driver,
discharging water with a short hose line.
(2) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the
enclosed cab. Water is discharged via a monitor or turret that is controlled from within the
apparatus.
(3) Driver is located inside the apparatus in a seated, belted position within the enclosed cab with one
or more fire fighters seated and belted in the on-board pump-and-roll fire-fighting position as
specified in Section 14.4.
(4) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the
enclosed cab, but water is discharged with a short hose line or hard line out an open cab window.
(5) And under no circumstances is it ever considered safe practice to ride standing or seated on the
exterior of the apparatus for mobile attack other than seated and belted in an on-board pump-and-
roll fire-fighting position. (See Section 6.3 of NFPA 1500.)
The on-board pump-and-roll fire-fighting position should only be used when the following conditions
are met:
(1) The apparatus is actively engaged in mobile attack on the fire line.
(2) The fuel model is characterized as fine fuels.
(3) The ground is level, flat, and free of obstacles.
(4) Driver visibility is unobstructed.
(5) Vehicle speeds are no greater than 10 mph.
(6) Fire fighter is wearing full protective NFPA 1977-compliant personal protective equipment and is
equipped with a fire shelter.
A.14.4.3.4 This is to protect against objects such as limbs entering the seating enclosure. Woven wire
cloth with ¼ in. (0.6 cm) diameter wire spaced at 1¾ in. (4.4 cm) on centers is commonly used in the
forestry industry to provide this protection.
4. Add new A.14.1.1 to read as follows:
A.14.1.1 Typically, while engaged in fire-fighting operations on structural fires, apparatus are
positioned in a safe location, and hose is extended as necessary to discharge water or suppressants on
the combustible material.
In wildland fire suppression, mobile attack is often utilized in addition to stationary pumping. In
mobile attack, sometimes referred to as “pump-and-roll,” water is discharged from the apparatus while
the vehicle is in motion. Pump-and-roll operations are inherently more dangerous than stationary
pumping because the apparatus and personnel are in close proximity to the fire combined with the
additional exposure to hazards caused by a vehicle in motion, often on uneven ground. The personnel
and/or apparatus could thus be more easily subject to injury or damage due to accidental impact,
rollover, and/or environmental hazards, including burn over.
To potentially mitigate against the increased risk inherent with pump-and-roll operations, the
following alternatives are provided for consideration:
(1) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the
enclosed cab. Water is discharged via a monitor or turret that is controlled from within the
apparatus.
(2) Driver and fire fighter(s) are located inside the apparatus in a seated, belted position within the
enclosed cab, but water is discharged with a short hose line or hard line out an open cab window.
(3) Driver is located inside the apparatus in a seated, belted position within the enclosed cab with one
or more fire fighters seated and belted in the on-board pump-and-roll fire-fighting position as
described in a following section.
(4) Driver is located inside the apparatus in a seated, belted position within the enclosed cab. Fire
fighter(s) is located outside the cab, walking alongside the apparatus, in clear view of the driver,
discharging water with a short hose line.
Under no circumstances is it ever considered a safe practice to ride standing or seated on the exterior
of the apparatus for mobile attack other than seated and belted in an on-board pump-and-roll fire-
fighting position.
摘要:

NFPA 1906-2016 amd3-2017 是美国国家消防协会发布的关于野外消防车辆及其设备的标准规范,其中 amd3-2017 表示2017年发布的第三次修正案。该标准规定了用于野外火灾扑救的专用车辆设计、性能、测试和维护要求,旨在确保消防人员在使用这些设备时具备更高的安全性和操作效率。修正案进一步更新了技术条款,包括对车辆制动系统、照明、泵性能及载重能力的优化,以适应日益复杂的野外火灾场景。本规范适用于制造、采购及检验野外消防设备的单位,是消防行业和市政部门制定车辆技术标准的权威参考文

展开>> 收起<<
NFPA 1906-2016 amd3-2017.pdf

共5页,预览4页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:阿拉丁 分类:国外协会 价格:8星币 属性:5 页 大小:40.89KB 格式:PDF 时间:2024-09-16

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 5
客服
关注