AATCC TM82-2022 Test Method for Fluidity of Dispersions of Cellulose from Bleached Cotton Cloth 漂白棉布纤维素分散液流动性的试验方法

VIP免费
那山那人那狗 2025-04-27 19 221.85KB 3 页 15星币
侵权投诉
Copyright © 2022 American Association of Textile Chemists and Colorists
AATCC Manual of International Test Methods and Procedures/2023 AATCC TM82-2022 133
1. Purpose and Scope
1.1 The test procedures in this test
method are applicable to bleached, unfin-
ished cotton cloth. The fluidity of a dis-
persion of bleached cellulose fibers in cu-
priethylene diamine solvent is a sensitive
measure of the degradation of the cellu-
lose resulting from the action of acids, al-
kalis, oxidizing or reducing agents. It is
therefore useful in determining the com-
pleteness of the bleaching treatment to
which the cloth has been subjected, as
well as the effect of chemical treatments
on the tensile strength of the cloth. (Flu-
idity of dispersions in cuprammonium
hydroxide has been dropped from this
test method; see 11.1 for details.)
2. Principle
2.1 The length of chain of cellulose
molecules is decreased when treated with
acid, alkali, oxidizing or reducing agents,
etc. The severity of the treatment deter-
mines the extent of the shortening of the
cellulose chain and the fluidity, or ease of
flow, of a dispersion of the cellulose in
the solvents.
3. Terminology
3.1 fluidity, n.—of a cellulose solu-
tion, a measure of the ease of flow or mo-
tion of a solution, and therefore, an indi-
cator of the molecular weight of the
cellulose.
3.2 rhe, n.—the unit of fluidity; the re-
ciprocal of the unit of viscosity (the
poise).
4. Safety Precautions
NOTE: These safety precautions are
for information purposes only. The pre-
cautions are ancillary to the testing proce-
dures and are not intended to be all inclu-
sive. It is the user’s responsibility to use
safe and proper techniques in handling
materials in this test method. Manufac-
turers MUST be consulted for specific
details such as material safety data sheets
and other manufacturers recommenda-
tions. All OSHA standards and rules
must also be consulted and followed.
4.1 Good laboratory practices should
be followed, Wear safety glasses in all
laboratory areas.
4.2 All chemicals should be handled
with care. Use chemical goggles or face
shield, impervious gloves and an imper-
vious apron during dispensing and mix-
ing. CAUTION: Always add acid to
water.
4.3 An eyewash/safety shower should
be located nearby and a self-contained
breathing apparatus should be readily
available for emergency use.
4.4 Exposure to chemicals used in this
procedure must be controlled at or below
levels set by governmental authorities
(e.g., Occupational Safety and Health
Administration’s [OSHA] permissible ex-
posure limits [PEL] as found in 29 CFR
1910.1000; see web site: www.osha.gov
for latest version). In addition, the Ameri-
can Conference of Governmental Indus-
trial Hygienists (ACGIH) Threshold
Limit Values (TLVs) comprised of time
weighted averages (TLV-TWA), short
term exposure limits (TLV-STEL) and
ceiling limits (TLV-C) are recommended
as a general guide for air contaminant ex-
posure which should be met (see 11.2).
5. Materials and Reagents
5.1 Cupriethylene diamine, 1.0 M solu-
tion.
5.2 Nitrogen (N2)
5.3 Ostwald Cannon-Fiske viscometers
(see Fig. 1 and 11.3).
6. Preparation of Sample
6.1 Use a representative sample of
bleached and unfinished cloth weighing
not less than 5g.
6.2 Cut the sample by use of a cutting
mill with a 20-mesh sieve and top deliv-
ery tube, so that short individual fibers
about 1.5 mm (0.06 in.) long are obtained.
6.3 Run duplicate tests, using fibers
from the one sample. Divide the cut sam-
ple into two portions of approximately
equal weight and store in separate con-
tainers overnight in a desiccator contain-
ing conc. sulfuric acid. Samples condi-
tioned in this manner will have a
moisture content of 2%.
6.4 The purpose of dividing the sample
into two portions is to reduce the time of
exposure to the atmosphere during
weighing. The weight of the specimen for
the fluidity determination should be suffi-
cient to give a 0.5% solution of the cotton.
7. Preparation of Solutions
7.1 Prepare 0.167 M cupriethylene di-
amine solution by diluting 161 mL of the
1.0 M solution with freshly boiled and
cooled water to 1.0 L in a volumetric
flask, observing all precautions to ex-
clude air.
7.2 Store the reagents at all times under
oxygen-free nitrogen to minimize decom-
position.
7.3 Measure the 1.0 M and 0.161 M so-
lutions from burettes of known accuracy.
The burettes may be attached to the re-
agent storage bottles by means of a side
arm sealed into the lower part of the bu-
rette and filled by application of nitrogen
pressure on the storage bottle,
8. Procedure
8.1 Ostwald Cannon-Fenske-type vis-
cometers (see Fig. 1) having the charac-
teristics shown in Table I are suitable for
determining fluidities in the range nor-
mally found for bleached cotton. It is rec-
ommended that the efflux time (see 8.9)
exceed 100 s in order to ensure accuracy.
8.2 Weigh 0.4-0.45 g of the sample,
prepared as previously described to the
nearest 0.1 mg. Remove the samples
from the desiccator one at a time, and
make the weighings as quickly as possi-
ble to prevent additional moisture pickup
from the air.
8.3 Transfer the fibers carefully from
the weighing dish or watch glass to an ap-
proximately 120 mL (4 oz.) widemouth
amber glass bottle.
8.3.1 To the specimen in the solution
bottle, add X mL of 0.167 M cupriethyl-
ene diamine solution, where X is calcu-
lated as follows:
X = 120 × weight of specimen × 0.98
8.4 Sweep out the air in the bottle
above the solution by applying a brisk
stream of purified nitrogen over the sur-
AATCC TM82-2022
Test Method for Fluidity of Dispersions
of Cellulose from Bleached Cotton Cloth
Fig. 1—Ostwald Cannon-Fenske
cuen viscosimeter.
Copyright The American Association of Textile Chemists and Colorists
Provided by Accuris under license with AATCC
Licensee=Underwriters Laboratories - Ho Chi Ming City, Vie/5909636157, User=Le,
Not for Resale, 11/23/2023 20:10:19 MST
No reproduction or networking permitted without license from Accuris
--``,`,,,``,,```,`,,,,,,`````,-`-`,,`,,`,`,,`---
Copyright © 2022 American Association of Textile Chemists and Colorists
134 AATCC TM82-2022 AATCC Manual of International Test Methods and Procedures/2023
face of the solution for 20 s, and quickly
screw the cap of the bottle in place.
8.5 Shake the bottle by means of an
automatic shaker at intermediate speed
for 2 h.
8.6 Remove the bottle from the shaker
and add to the solution Y mL of 1.0 M
cuen, where Y is calculated as follows:
Y = 80 × weight of specimen × 0.98
8.7 Repeat the nitrogen treatment and
bottle-shaking as described, with the ex-
ception that the shaking time should be 3 h.
8.8 Permit the bottle to stand for 30
min after removing from the shaker and
before loading the viscometer. The vis-
cometer should be flushed with nitrogen
gas prior to being loaded with the disper-
sion. The viscometer is loaded by invert-
ing it with the capillary side arm sub-
merged in the cellulose dispersion and
applying suction to the other arm of the
instrument. Draw the dispersion into both
the bulbs on the capillary arm to the
etched mark. Rotate the pipette to its nor-
mal vertical position, and place the vis-
cometer in a constant-temperature water
bath at 25 ± 1°C (77 ± 2°F). The liquid
will drain into the lower reservoir and
will reach temperature equilibrium with
the bath (approx. 5 min).
8.9 Determine the efflux time by draw-
ing the liquid above the mark between the
two bulbs and measuring the time for the
meniscus to pass from the mark between
the two bulbs to the mark below the
lower bulb. Take the average of two or
more observations.
9. Calculations
9.1 The fluidity in rhes, F, is calculated
as follows:
F = 100/ctd
where:
c= instrument constant determined
from a liquid of known viscosity.
t= time of discharge of the liquid
within the ring interval in seconds.
d= density of cuen solution, 1.052.
10. Report
10.1 Describe or identify the bleached
and unfinished cloth sample.
10.2 Report that sample was tested us-
ing AATCC TM 82 - 2022
10.3 Report the average efflux time.
11. Precision and Bias
11.1 Precision Estimate.
11.1.1 Single Laboratory Study. Esti-
mates of Components of Variance for
technicians (VO) and residual error (V),
and their associated Critical Differences,
CDm (multiple technicians in lab) and
CDo (single technician in lab) were de-
termined in a single laboratory in 2005.
Three technicians performed duplicate
tests on materials, according to 6.3 at
three treatment levels of no bleach (NB),
standard bleach (SB), and over bleached
(OB), using the Cuen Method.
11.1.2 95% Precision Estimates from
Individual Technician and Treatment Val-
ues. The results shown in Table II are the
average of two determinations by a single
technician. Based on these averages, the
components of variance (Vo) and residual
error (V) for each technician were com-
puted. As can be seen even in this limited
study, there was an apparent difference in
the results reported by Technician 3, for
each of the treatments. This is a very lim-
ited study, and caution is advised in the
application of these estimates to specific
testing scenarios (see Table II).
With three technicians involved in this
limited study, it was possible to assess the
effect of multiple technicians in test re-
sult comparisons by looking across tech-
nicians in treatments and calculating VO
(technician) and V (residual) components
of variance for each treatment. The above
summary shows rather large values for
CDm (multiple O in lab), due to the level
differences among technicians. This is a
very limited study, and caution is advised
in application of these estimates to spe-
cific testing scenarios. All of the above
considerations were based on a 95% con-
fidence level.
11.1.3 95% Precision Estimates from
Analysis of the Whole Data Set. Using
Analysis of Variance, Components of
Variance for technicians and residual
were computed and are shown in Table
III. As a result of the difference in results
reported by Technician 3, the values gen-
erated for CDm (multiple operators in a
single lab) were also high. These esti-
mates pertain only to within laboratory
precision. A much broader study, with
multiple laboratory participation, must be
made to yield reliable between laboratory
Table I—Viscosimeter Characteristics
Size No.
Approx. Range of
Efflux Time, s Capillary Diameter, cm Fluidity Range Rhes
200 100 to 700 0.097 to 0.103 1.43 to 10.0
300 100 to 700 0.120 to 0.130 0.80 to 04.0
400 100 to 700 0.180 to 0.190 0.1175 to 0.8300
Table II—Data Summary for Technicians and Treatments
TMT NB TMT SB TMT OB
Technician
Summaries
Te c h 0 1 Av (2 )
V
CDso
0.564
0.0013
0.070
0.811
0.0004
0.040
4.0330
0.0002
0.0300
V 0.0006
CDo 0.05
Te c h 0 2 Av (2 )
V
CDso
0.609
0.0003
0.030
0.885
0.0001
0.020
4.1720
0.00004
0.0100
V 0.00014
CDo 0.02
Te c h 0 3 Av (2 )
V
CDso
0.397
0.0022
0.090
0.745
0.0238
0.310
3.6250
0.0060
0.1500
V 0.0107
CDo 0.20
Treatment Summaries AV-Rhes Units
DC-Rhes Units
V-Rhes squaredTMT1 TMT2 TMT3
3 Tech (O=3) VO
V
0.0118
0.0012
0
0.0088
0.0795
0.0021
Single O
Multiple O
CDo
CDm
0.07
0.31
0.19
0.19
0.09
0.79
CD Equations: CDo=2.8 (V/2)^0.5 CDm=2.8 (V/2 + VO)^0.5
Table III—Components of Variance and 95% Precision Estimates
Components of Variance
Source COV Unit Var
O.L VO 0.0307
Res V 0.0038
95% Precision Estimates
Single O in Lab CDo 0.1200 CDso=2.8 (V/2)^0.5
Multiple O in Lab CDm 0.5100 CDw=2.8 (V/2) + VO)^0.5
Copyright The American Association of Textile Chemists and Colorists
Provided by Accuris under license with AATCC
Licensee=Underwriters Laboratories - Ho Chi Ming City, Vie/5909636157, User=Le,
Not for Resale, 11/23/2023 20:10:19 MST
No reproduction or networking permitted without license from Accuris
--``,`,,,``,,```,`,,,,,,`````,-`-`,,`,,`,`,,`---
Copyright © 2022 American Association of Textile Chemists and Colorists
AATCC Manual of International Test Methods and Procedures/2023 AATCC TM82-2022 135
estimates (see Table III).
11.2 Bias. The true value of fluidity of
dispersions of cellulose from bleached
cotton cloth can be defined only in terms
of a test method. There is no independent
method for determining the true value. In
estimating this property, the test method
has no known bias.
12. Notes
12.1 The cupriethylene diamine cuen
method is predominant in the United States as
well as some other parts of the world. The cu-
prammonium hydroxide cuam method has
been predominantly used in Great Britain.
AATCC Committee RA34 voted to drop the
cuam method in 2005 and to refer to British
Standard 2610:1978 “Method of test for the
determination of the cuprammonium fluidity
of cotton and certain ce11uosic man-made
fibres.” The Bleachers Handbook is also a
good reference for a discussion of the cuam
method (see 11.4).
12.2 Available from Publications Office,
ACGIH, Kemper Woods Center, 1330 Kemper
Meadow Dr., Cincinnati OH 45240; tel: +1.
513.742.2020; web site: www.acgih.org.
12.3 Uncalibrated viscometers can be cali-
brated by means of standard oils or other
reference liquids according to ASTM D445,
Method 6B.
12.4 The examples of fluidities shown in
the table in Fig. 2 are to be used as a guideline,
Other tests for damage may be necessary.
Consult “Analytical Methods for a Textile
Laboratory,” third edition, 1984, edited by J.
William Weaver, published by AATCC, for
further tests for damage. Although the source
of the data and the graph in Fig. 2 are not
known, it was maintained as a convenient ref-
erence for comparison of cuen to cuam data.
13.1 History
13.1 Revised in 2022 to align with the
AATCC Style Guide.
13.2 Editorially revised 2019; reaffirmed
2016, 2012; editorially revised, 2010, 2008,
revised 2007; editorially revised 2004; editori-
ally revised and reaffirmed 2001;revised
1996; editorially revised, 1990; editorially re-
vised and reaffirmed 1989; editorially revised
1988, 1985; reaffirmed 1984; editorially re-
vised 1983; reaffirmed, 1979, 1975; editori-
ally revised 1975, 1974; reaffirmed, 1972,
1968, 1961.
13.3 Developed in 1954 by AATCC RA34.
Fig. 2—Evaluation Cuam
and Cuen fluidities
Copyright The American Association of Textile Chemists and Colorists
Provided by Accuris under license with AATCC
Licensee=Underwriters Laboratories - Ho Chi Ming City, Vie/5909636157, User=Le,
Not for Resale, 11/23/2023 20:10:19 MST
No reproduction or networking permitted without license from Accuris
--``,`,,,``,,```,`,,,,,,`````,-`-`,,`,,`,`,,`---
摘要:

本页面详细解读标准规范文档《AATCC TM82-2022 Test Method for Fluidity of Dispersions of Cellulose from Bleached Cotton Cloth 漂白棉布纤维素分散液流动性的试验方法》。该标准由美国纺织化学师与印染师协会(AATCC)发布,旨在规范通过测定漂白棉布纤维素分散液的流动性能来评估纤维素的降解程度或聚合度变化。内容涵盖测试原理、试剂配制、样品制备、铜氨溶液分散液的操作步骤、流动时间测量及结果计算等关键环节。适用于

展开>> 收起<<
AATCC TM82-2022 Test Method for Fluidity of Dispersions of Cellulose from Bleached Cotton Cloth 漂白棉布纤维素分散液流动性的试验方法.pdf

共3页,预览3页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:那山那人那狗 分类:国外协会 价格:15星币 属性:3 页 大小:221.85KB 格式:PDF 时间:2025-04-27

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 3
客服
关注