ASTM C1112 - 99 (2005)

VIP免费
Carl 2024-09-02 13 447.04KB 9 页 12星币
侵权投诉
Designation: C 1112 – 99 (Reapproved 2005)
Standard Guide for
Application of Radiation Monitors to the Control and
Physical Security of Special Nuclear Material
1
This standard is issued under the fixed designation C 1112; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This guide briefly describes the state-of-the-art of radia-
tion monitors for detecting special nuclear material (SNM) (see
3.1.11) in order to establish the context in which to write
performance standards for the monitors. This guide extracts
information from technical documentation to provide informa-
tion for selecting, calibrating, testing, and operating such
radiation monitors when they are used for the control and
protection of SNM. This guide offers an unobtrusive means of
searching pedestrians, packages, and motor vehicles for con-
cealed SNM as one part of a nuclear material control or
security plan for nuclear materials. The radiation monitors can
provide an efficient, sensitive, and reliable means of detecting
the theft of small quantities of SNM while maintaining a low
likelihood of nuisance alarms.
1.2 Dependable operation of SNM radiation monitors rests
on selecting appropriate monitors for the task, operating them
in a hospitable environment, and conducting an effective
program to test, calibrate, and maintain them. Effective opera-
tion also requires training in the use of monitors for the security
inspectors who attend them. Training is particularly important
for hand-held monitoring where the inspector plays an impor-
tant role in the search by scanning the instrument over
pedestrians and packages or throughout a motor vehicle.
1.3 SNM radiation monitors are commercially available in
three forms:
1.3.1 Small Hand-Held Monitors—These monitors may be
used by an inspector to manually search pedestrians and
vehicles that stop for inspection.
1.3.2 Automatic Pedestrian Monitors—These monitors are
doorway or portal monitors that search pedestrians in motion as
they pass between radiation detectors, or wait-in monitoring
booths that make extended measurements to search pedestrians
while they stop to obtain exit clearance.
1.3.3 Automatic Vehicle Monitors—These monitors are por-
tals that monitor vehicles as they pass between radiation
detectors, or vehicle monitoring stations that make extended
measurements to search vehicles while they stop to obtain exit
clearance.
1.4 Guidance for applying SNM monitors is available as
Atomic Energy Commission/Nuclear Regulatory Commission
(AEC/NRC) regulatory guides, AEC/ERDA/DOE performance
standards, and more recently as handbooks and applications
guides published by national laboratories under DOE sponsor-
ship. This broad information base covering the pertinent
physics, engineering practice, and equipment available for
monitoring has had no automatic mechanism for periodic
review and revision. This ASTM series of guides and standards
will consolidate the information in a form that is reexamined
and updated on a fixed schedule.
1.5 Up-to-date information on monitoring allows both
nuclear facilities and regulatory agencies to be aware of the
current range of monitoring alternatives. Up-to-date informa-
tion also allows manufacturers to be aware of the current goals
of facilities and regulators, for example, to obtain particular
sensitivities at a low nuisance alarm rate with instrumentation
that is dependable and easy to maintain.
1.6 This guide updates and expands the scope of NRC
regulatory guides and AEC/ERDA/DOE SNM monitor perfor-
mance standards using the listed publications as a technical
basis.
2
1.7 The values stated in SI units are to be regarded as the
standard.
1.8 This standard may involve hazardous materials, opera-
tions, and equipment. This standard does not purport to
address all of the safety problems associated with its use. It is
the responsibility of the user of this standard to establish
1
This guide is under the jurisdiction of ASTM Committee C26 on Nuclear Fuel
Cycle and is the direct responsibility of Subcommittee C26.12 on Safeguard
Applications.
Current edition approved June 1, 2005. Published October 2005. Originally
approved in 1988. Last previous edition approved in 1999 as C 1112 – 99.
2
Copies of out-of-print references may be available from Group NIS6, MS-J562,
Los Alamos National Laboratory, Los Alamos, NM 87545.
1
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 08:27:12 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
appropriate safety and health practices and determine the
applicability of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
3
C 859 Terminology Relating to Nuclear Materials
C 993 Guide for In-Plant Performance Evaluation of Auto-
matic Pedestrian SNM Monitors
C 1189 Guide to Procedures for Calibrating Automatic
Pedestrian SNM Monitors
C 1236 Guide for In-Plant Performance Evaluation of Au-
tomatic Vehicle SNM Monitors
C 1237 Guide for In-Plant Performance Evaluation of
Hand-Held SNM Monitors
2.2 Code of Federal Regulations:
Title 10, Part 73, Physical Protection of Plants and Materi-
als
4
2.3 AEC/NRC Regulatory Guides:
5.27 Special Nuclear Material Monitors, June 1974
5
5.7 Control of Personnel Access to Protected Areas, Vital
Areas, and Material Access Areas, May 1980
5
2.4 AEC/ERDA/DOE SNM Monitor Standards:
Personnel Doorway Monitor Standards, January 1974
6
Standards for Hand-Held SNM Detection Instruments for
Personnel, Package, and Vehicle Search, April 1974
6
2.5 NRC NUREG and NUREG/CR Reports:
NUREG 1321, Testing Standards for Physical Security
Systems at Category I Fuel Cycle Facilities, October
1991
5
NUREG 1329, Entry/Exit Control at Fuel Fabrication Fa-
cilities Using or Possessing Formula Quantities of Strate-
gic Special Nuclear Material, November 1985
5
NUREG/CR 5899 (SAND 92-1339), Entry/Exit Control
Components for Physical Protection Systems, 1992
5
3. Terminology
3.1 Definitions of Terms Specific to This Standard:
3.1.1 alternative test sources—there are no other radioac-
tive isotopes that individually or together can duplicate the
radioactive emissions of SNM. Hence, performance testing in
a laboratory environment will use only SNM test sources.
Operational testing at the recommended three-month interval
can most often use SNM test sources, although sometimes a
more readily available equivalent-intensity highly enriched
uranium (HEU) source may be used in place of a very
expensive and hard to obtain plutonium source. The more
frequent daily or weekly operational testing will often substi-
tute alternative isotopic sources. Often these are continuity
tests that can use the cesium-137 (
137
Cs) sources that are on
hand for pulse height calibration. Also barium-133 (
133
Ba) may
be used when a gamma-ray spectrum similar to plutonium is
needed to make a daily or weekly test that must roughly
approximate testing with a particular plutonium test source.
Gas lantern mantles containing thorium are radioactive and
sometimes are used to test continuity in hand-held monitors.
3.1.2 detection sensitivity—specified in terms of the mass of
SNM that will be detected 50 % or more of the time when
carried through the monitor in a specified fashion. This
convenient definition greatly simplifies SNM monitor perfor-
mance testing and makes it possible to readily verify sensitivity
by performing an experiment that mimics the monitor’s normal
use. The related masses that would be detected 95 % or 99 %
of the time can be estimated from the 50 % mass but would be
impractical to determine with high confidence by themselves.
Experiments conducted to determine or verify sensitivity must
be thorough enough to have an upper 95 % confidence coeffi-
cient so that repeating the experiment will probably give the
same result.
3.1.3 monitoring—the process of detecting increased radia-
tion intensity by making one or more measurements of the
intensity in the vicinity of a pedestrian or motor vehicle for
comparison with an alarm threshold derived from the expected
background radiation intensity.
3.1.4 NaI(Tl) detector—an inorganic sodium iodide (thal-
lium activated) (NaI(Tl)) scintillation detector that has inher-
ently good gamma-ray sensitivity but poor neutron response.
3.1.5 nuisance alarms—an alarm not caused by SNM but
by one of a number of other causes. For example, the statistical
variation in the measurement process, natural or process-
induced background intensity increases, or the presence of
non-SNM radiation emitters, among other things, may increase
a monitor’s measurement result by enough to cause an alarm.
Nuisance alarms from statistical variation, by design, are the
only ones present during testing and are the ones of concern in
designing and evaluating SNM monitors. These statistical
alarms are expressed in terms of alarms per comparison (test)
or, more importantly, alarms per passage, which may include a
number of comparisons. A monitor’s susceptibility to statistical
alarms and its detection sensitivity are directly related.
3.1.6 passthrough monitor—a radiation monitor that allows
free passage as it makes monitoring measurements and does
not require the person or vehicle being monitored to stop unless
it alarms.
3.1.7 plastic scintillation detector—a solid organic scintil-
lator that responds to both gamma rays and energetic neutrons
through scattering interactions between the incident radiation
and electrons or protons in the scintillator.
3.1.8 radiation detector—( 1) a detector consisting of a
scintillating material and attached photomultiplier tube that
produces light from neutron or gamma-ray interactions and
converts the light to electrical signals. (2) a neutron propor-
tional counter containing a converter gas to produce electrical
signals from neutron interactions.
3.1.9 standard SNM performance test source—a metallic
sphere or cube of SNM having maximum self-attenuation of its
emitted radiation and an isotopic composition to minimize that
emission. Such minimum radioactive emission sources as
described in 3.1.9.1 and 3.1.9.2 allow testing with the worst-
case forms of SNM. As a result of worst-case testing, routine
3
Annual Book of ASTM Standards, Vol 12.01.
4
Available from the Superintendent of Documents, U.S. Government Printing
Office, Washington, DC 20402.
5
Available from the U.S. Nuclear Regulatory Commission, Washington,
DC 20555.
6
Chapter 4, Entry-Control Systems Handbook, SAND77-1033, Sandia National
Laboratories, Albuquerque, NM 87185.
C 1112 – 99 (2005)
2
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 08:27:12 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
operation of a tested monitor in a plant achieves as good or
better performance and the monitor will detect the same or
smaller masses of process SNM.
3.1.9.1 special nuclear material (SNM)—plutonium with an
isotopic content of at least 93 % plutonium-239 (
239
Pu) and
less than 6.5 % plutonium-240 (
240
Pu). The plutonium should
contain less than 0.5 % impurities. The form of the material
should be a metallic sphere or cube. The impact of americium-
241 (
241
Am), a plutonium decay product that will build up in
time and emit increasing amounts of 60-keV gamma radiation,
must be minimized by including a cadmium filter 0.04 to
0.08-cm thick as part of the source encapsulation. Protective
encapsulation should be in as many layers as local rules require
of a material such as aluminum (#0.32-cm thickness) or thin
(#0.16-cm thickness) stainless steel or nickel that minimize
unnecessary radiation absorption.
3.1.9.2 standard uranium test source—highly enriched ura-
nium (HEU) containing at least 93 % uranium-235 (
235
U) and
less than 0.25 % impurities. The form of the material should be
a metallic sphere or cube. Encapsulation should be thin plastic
or thin aluminum (#0.32-cm thickness) to minimize unneces-
sary radiation absorption in the encapsulation.
3.1.10 special nuclear material (SNM)—plutonium of any
isotopic composition,
233
U, or enriched uranium as defined in
Terminology C 859. This is the term normally used to describe
monitors designed for monitoring SNM or strategic SNM,
which is plutonium, uranium-233, and uranium enriched to
20 % or more in the
235
U isotope.
3.1.11 special nuclear material (SNM) monitor— a radia-
tion detection system that measures ambient radiation intensity,
determines an alarm threshold from the result, and then when
it is monitoring, alarms if that threshold is exceeded.
3.1.12 wait-in monitor—a radiation monitor in which the
person or vehicle being monitored is required to stop and
remain stationary during monitoring measurement.
4. Significance and Use
4.1 SNM monitors are an efficient and sensitive means of
unobtrusively (without a body search) meeting the require-
ments of 10 CFR (Code of Federal Regulations) Part 73 or
DOE Order 5632.4 (May 1986) that individuals exiting nuclear
material access areas (MAAs) be searched for concealed SNM.
The monitors sense radiation emitted by SNM, which is an
excellent but otherwise imperceptible clue to the presence of
the material. Because the monitors operate in a natural radia-
tion environment and must detect small intensity increases as
clues, the monitors must be well designed and maintained to
operate without unnecessary nuisance alarms.
4.2 This guide provides information on different types of
monitors for searching pedestrians and vehicles. Each monitor
has an inherent sensitivity at a particular nuisance alarm rate
that must be low enough to maintain the monitor’s credibility.
Sensitivity and nuisance alarm rates are both governed by the
alarm threshold so it is very important that corresponding
values for both be known when measured, estimated, or
specified values are discussed. Fitting SNM monitors into a
facility physical protection plan must not only consider ad-
equate sensitivity but also a sufficiently low nuisance alarm
rate.
5. Types of SNM Monitors
5.1 Hand-Held Monitors—These small, battery-powered,
computer-operated instruments (Fig. 1) measure ambient back-
ground intensity (over8sorso)andthen calculate an alarm
threshold on power-up or push-button command. Otherwise,
they continuously monitor, making short measurements (0.05 s
long averaged over 0.4 s, for example) and then comparing the
results to the alarm threshold. Hand-held monitor detectors
may be gamma-ray sensitive NaI(Tl) detectors or, more com-
monly, plastic scintillation detectors that sense both gamma
rays and neutrons (1-3).
7
The operator of a hand-held monitor
scans (at about 0.5 m/s) the instrument over every surface of a
pedestrian or vehicle, coming within 5 to 15 cm (2 to 6 in.) of
all possible locations for SNM (4).
5.1.1 Frequent or continuous alarms in a particular region
are clues that inform the operator of the presence and location
of SNM. Occasional alarms from statistical variation in count-
ing do not detract from searching so a very low alarm threshold
7
The boldface numbers in parentheses refer to the list of references at the end of
this guide.
NOTE—Hand-held monitors are computer-based radiation detection
systems that operate on battery power. The operator plays an important
part in effective hand-held monitoring
FIG. 1 Hand-Held Monitors
C 1112 – 99 (2005)
3
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 08:27:12 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
摘要:

ASTM C1112 - 99 (2005) 是一项由美国材料与试验协会(ASTM)制定的标准规范,主要涉及太阳能吸收系数的测试方法,适用于平板太阳能集热器及相关隔热材料的性能评估。该标准最初于1999年发布,2005年进行了重新确认,旨在提供一致且可重复的测试程序,以测量材料表面吸收太阳辐射的能力。通过应用该标准,工程师和研究人员能够准确评估太阳能集热器中吸热涂层或吸热板的吸热效率,从而优化太阳能热利用系统的整体性能。此标准对于太阳能行业的产品开发、质量控制以及性能对比具有重要参考价值,尤其适