function of the amount and characteristics of clay minerals
present in the test specimen. High methylene blue values
indicate increased potential for diminished fine aggregate or
mineral filler performance in a cementitious mixture due to the
presence of clays.
NOTE 1—Results from this test method are not expected to be correlated
with those obtained using AASHTO T 330 or EN 933-9. These three test
methods are likely to give very different numerical values even though the
units are the same. The AASHTO T 330 test is performed only on the
fraction of an aggregate passing the 75 µm sieve, the EN 933-9 test is
performed only on the fraction finer than 2 mm, and this test is performed
on the fraction finer than the 4.75 mm sieve. Therefore, when testing the
same fine aggregate source, the AASHTO test method would give the
highest methylene blue value because any clay present in the specimen
would be concentrated in the fraction finer than the 75 µm sieve. The
AASHTO and EN test methods do not take into account the amount of
material passing the 75 µm sieve or 2 mm sieve, respectively. For
example, a fine aggregate with high methylene blue value measured by the
AASHTO method but low percentage passing the 75 µm sieve may have
less effect on concrete performance than a fine aggregate with low
methylene blue value measured by the AASHTO method but a high
percentage passing the 75 µm sieve. In contrast, this test method expresses
methylene blue value based on the entire fine aggregate or mineral filler
specimen. Additionally, the AASHTO and EN test methods use titration to
determine the amount of methylene blue of known concentration that is
adsorbed by a specimen and require the operator to visually determine the
end point of the test. In contrast, this test method uses a colorimeter to
detect the change in concentration of methylene blue solution before and
after being mixed with the fine aggregate or mineral filler specimen.
NOTE 2—Recommendations for maximum methylene blue values for
specific applications are not provided in this test method. Maximum
methylene blue values should be established based on successful perfor-
mance of fine aggregate or mineral filler in the applications under
consideration.
6. Interferences
6.1 Methylene blue will degrade when exposed to light.
Store in darkness. No appreciable degradation occurs during
the time it takes to complete the test method.
6.2 Methylene blue will stain glassware and plastic ware.
Therefore, do not reuse such apparatus.
7. Apparatus
7.1 4.75-mm sieve conforming to Specification E11.
7.2 Mass balance having a capacity of 50 g or more and
capable of measuring to the nearest 0.1 g or less.
7.3 Micropipette capable of measuring to the nearest 1 µL.
7.4 Colorimeter capable of reading absorbance of a speci-
men at a wavelength of 610 61 nm at operating temperatures
of at least 0 to 50ºC. The colorimeter shall be able to read
absorbance between zero and the absorbance associated with a
0.144 % mass concentration of methylene blue solution.
7.5 Disposable items for each test—two plastic 50-mL test
tubes, one plastic 1-mL vial, one 3-mL syringe with Luer-Lok
adapter, one 0.2-µm syringe filter, one colorimeter glass cuvette
(or sample cell), one micropipette tip, and two transfer pipettes.
7.6 Additional disposable items for confirming methylene
blue starting concentration—plastic 50-mL test tube, colorim-
eter glass cuvette, micropipette tip, and transfer pipette.
7.7 Additional disposable items for standardizing the
colorimeter—plastic 50-mL test tube, colorimeter glass
cuvette, micropipette tip, and transfer pipette.
7.8 Drying apparatus—A ventilated oven capable of main-
taining a uniform temperature of 110 65°C. Other suitable
drying apparatuses shall be permitted, such as an electric hot
plate or heat lamp. The temperature of the specimen shall not
exceed 150°C. In cases where the fine aggregate or mineral
filler itself is altered by temperature greater than 115°C, use a
ventilated, controlled-temperature oven at 110 65°C.
NOTE 3—Drying by means other than a ventilated oven may be
appropriate for field use.
8. Reagents and Materials
8.1 Purity of reagents—reagent grade methylene blue shall
be used in all tests.
8.2 Purity of water—references to water shall be understood
to mean distilled or deionized water.
8.3 Methylene blue test solution—a 0.50 % mass concentra-
tion methylene blue solution based on mass of trihydrate
methylene blue in water.
NOTE 4—Methylene blue is available in both anhydrous and trihydrate
form and can also be obtained in solution form. This test is based on the
mass of the trihydrate form.
9. Sampling, Test Specimens, and Test Units
9.1 Sample fine aggregate in accordance to Practice D75/
D75M.
9.2 Thoroughly mix the sample and reduce it as necessary
using the applicable procedures in Practice C702/C702M.
9.3 If it appears necessary, dampen the material to avoid
segregation or loss of fines during specimen preparation.
9.4 Obtain at least 30 g of material passing the 4.75-mm
sieve in the following manner:
9.4.1 Separate the sample on the 4.75-mm sieve by means
of a lateral and vertical motion of the sieve, accompanied by a
jarring action so as to keep the sample moving continuously
over the surface of the sieve. Continue the sieving until not
more than 1 mass % of the residue passes the sieve during the
1-min sieving operation. Perform the sieving operation either
by hand or by a mechanical apparatus. When thoroughness of
mechanical sieving is being determined, test by the hand
method described above using a single layer of material on the
sieve.
9.4.2 Break down any lumps of material in the coarse
fraction to pass the 4.75-mm sieve. Use a mortar and rubber-
covered pestle or any other means that will not fracture
aggregate particles. Add this additional material passing the
sieve to the separated fine portion of the sample and mix
thoroughly.
9.5 Dry the test specimen to constant mass by means of the
selected source of heat, and cool to room temperature before
testing. The sample is thoroughly dry when further heating
causes, or would cause, less than 0.1 g additional loss in mass.
9.6 Repeat the procedures in 9.4 and 9.5 to obtain three test
specimens.
C1777 − 20