cardboard tabbed specimens serrated jaws are generally used.
Jaws should be inspected regularly and cleaned or repaired as
required.
6.1.4.3 Extensometer and Recorder—An extensometer and
recording device in accordance with the requirements of
Practice E83 Class B-2 are required. The extensometer and
recorder shall be coordinated with the tensile testing machine
so that the corresponding load and elongation of the specimen
are recorded at essentially the same time.
6.1.4.4 Balance, Analytical—Accuracy of 60.0002 g for
mass per unit length, density, and resin or sizing content
determinations.
6.1.4.5 Balance, Laboratory—Accuracy of 60.1 g for
measuring components of resin.
6.1.4.6 Length Measuring Devices—Devices to measure the
length of impregnated and consolidated specimens and dry
fiber to 62 mm accuracy are required.
6.1.4.7 Density Measuring Device—See Test Methods D70,
D3800, or D5550.
6.1.4.8 Forced Air Oven—A forced air oven of sufficient
sizing and temperature capabilities to cure the impregnated
fiber on the curing device. The temperature shall be controlled
to 610 °C.
7. Reagents and Materials
7.1 Reagent Water—Unless otherwise indicated, references
to water shall be understood to mean reagent water as defined
by Type III of Specification D1193.
7.2 Resin.
7.3 Commercial Grade Solvent, (optional) for resin dilution.
7.4 Hardener or Catalyst.
7.5 Surfactant (optional).
8. Test Specimens
8.1 Mass per Unit Length Specimen—The specimen to
measure mass per unit length is an 1 m minimum length of
fiber in the form in which it is intended to be used. Test one
specimen per sample. Coil the specimen into a usable form for
testing. Care is required to not damage and lose filaments from
the specimen.
8.2 Density Specimen—Density specimens may be sized,
unsized, or desized material. Unsized or desized samples are
preferred. Test one specimen per sample. An 1 m minimum
length is required for Test Method D3800. For methods in Test
Methods D70 and D5550, a suitable volume to fill the
container is recommended. Coil the specimen into a usable
form for testing. Care is required to not damage and lose
filaments from the specimen.
8.3 Tensile Test Specimen—The tensile specimen shall be a
tabbed or untabbed resin-impregnated and consolidated fiber.
Tabbed specimens shall have a 150 mm 65 mm gauge length
between the tabs. Untabbed specimens shall be of sufficient
length to allow a 150 mm 65 mm gauge length between the
grips when they are tested. Samples with 3000 filaments or less
may be tested using specimens of more than one fiber bundle
to facilitate handling. Combine the bundles before resin im-
pregnation and count the test results as one specimen. Test a
minimum of four test specimens per sample. Separate test
specimens for modulus and strength determination are permit-
ted; however, four specimens for each test are required.
Specimens that are fuzzy, curved, not uniform in cross section,
have broken filaments, resin lumps, or other observable defects
should be rejected unless they are representative of the material
being tested.
9. Conditioning
9.1 Fibers that adsorb less than 0.5 % moisture by weight at
23°C 62 °C and 90 % or greater relative humidity require no
conditioning before testing. Conduct mass per unit length,
density, and tensile testing for these materials at 23 °C 67 °C
and 50 % 620 % relative humidity unless other conditions are
the variables of interest.
9.2 Fibers that adsorb more than 0.5 % moisture by weight
at 23 °C 62 °C and 90 % or greater relative humidity require
conditioning before testing. Condition fibers at 23 °C 62 °C
and 50 % 610 % relative humidity for a minimum of 24 h.
Conduct mass per unit length and density testing at 23 °C 6
2 °C and 50 % 610 % relative humidity unless other condi-
tions are the variables of interest. Conduct tensile testing at
23 °C 67 °C and 50 % 610 % relative humidity unless other
conditions are the variables of interest.
9.3 To determine moisture adsorption, dry a minimum of
five mass per unit-type specimens at 120 °C 65 °C for 24 h in
a circulating air oven. Cool the specimens in a desiccator.
Remove the specimens from desiccator one at a time and
immediately weigh them. Place the specimens in a humidity
chamber and maintain at 23 °C 62 °C and 90 % or greater
relative humidity for 24 h. Remove the specimens from the
humidity chamber one at a time and weigh immediately.
9.4 If all specimens are conditioned for 24 h and mass per
unit length and density testing are performed at 23 °C 62 °C
and 50 % 610 % relative humidity, then no testing for
moisture adsorption is required.
9.5 Moisture adsorption testing is only required once annu-
ally for a standard product.
10. Specimen Preparation
10.1 Mass per Unit Length—No preparation is required. The
sample is taken from a package of material as it is intended to
be used.
10.2 Density—The preferred density specimen is a desized
or unsized fiber. This eliminates any need to correct for the
density of the sizing. The sizing may be removed using solvent
extraction, pyrolysis, or other means. An example method is
described in Appendix X1. An unsized sample of a sized fiber
would have to be collected during the production of the fiber
and is therefore not recommended.
10.3 Tensile Test—The tensile test specimen must be im-
pregnated with resin and consolidated before testing.
10.3.1 Resin Preparation—Any resin that meets the require-
ments of 4.5 may be used. The resin when combined with the
fiber shall produce a composite (reinforcement/matrix) failure.
D4018 − 23
3