3.5 For definitions of other terms used in this guide, refer to
Guide E729 and Terminology E943. For an explanation of
units and symbols, refer to IEEE/ASTM SI 10.
4. Summary of Guide
4.1 In each of two or more treatments, test organisms of one
species are maintained for 2 days to 8 days in one or more test
chambers. In each of the one or more control treatments, the
organisms are maintained in dilution water to which no effluent
has been added in order to provide (1) a measure of the
acceptability of the test by giving an indication of the quality
of the test organisms and the suitability of the dilution water,
test conditions, handling procedures, and so forth, and (2) the
basis for interpreting data obtained from the other treatments.
In each of the one or more other treatments, the organisms are
maintained in dilution water to which a selected concentration
of effluent has been added. Data on effects on the organisms in
each test chamber are usually obtained periodically during the
test and analyzed to determine LC50s or EC50s for various
lengths of exposure.
5. Significance and Use
5.1 An acute effluent toxicity test is conducted to obtain
information concerning the immediate effects on test organ-
isms of a short-term exposure to an effluent under specific
experimental conditions. One can directly examine acute
effects of complex mixtures of chemicals as occurs in effluents
and some ambient waters. Acute effluent toxicity tests can be
used to evaluate the potential for designated-use or aquatic life
impairment in the receiving stream, lake, or estuary. An acute
toxicity test does not provide information about whether
delayed effects will occur, although a post-exposure observa-
tion period, with appropriate feeding if necessary, might
provide such information.
5.2 Results of acute effluent tests might be used to predict
acute effects likely to occur on aquatic organisms in field
situations as a result of exposure under comparable conditions,
except that (1) motile organisms might avoid exposure when
possible, (2) toxicity to benthic species might be dependent on
sorption or settling of components of the effluent onto the
substrate, and (3) the effluent might physically or chemically
interact with the receiving water.
5.3 Results of acute effluent tests might be used to compare
the acute sensitivities of different species and the acute
toxicities of different effluents, and to study the effects of
various environmental factors on results of such tests.
5.4 Acute tests are usually the first step in evaluating the
effects of an effluent on aquatic organisms.
5.5 Results of acute effluent tests will depend on the
temperature, composition of the dilution water, condition of the
test organisms, exposure technique, and other factors.
6. Apparatus
6.1 Facilities—Although some small organisms can be held
and acclimated in static or renewal systems, most organisms
are held, acclimated, and cultured in flow-through systems.
Test chambers should be in a constant-temperature room,
incubator, or recirculating water bath. A dilution-water tank,
which may be used to store receiving water, or a headbox is
often elevated so dilution water can be gravity-fed into holding
and acclimation tanks and test chambers. Pumps are often used
to deliver dilution water and effluent to headboxes and tanks.
Strainers and air traps should be included in the water supply.
Headboxes and holding, acclimation, culture, and dilution-
water tanks should be equipped for temperature control and
aeration (see 8.3). Air used for aeration should be free of
fumes, oil, and water; filters to remove oil and water are
desirable. Filtration of air through a 0.22 µm bacterial filter
might be desirable (1)
4
. The facility should be well ventilated
and free of fumes. To further reduce the possibility of contami-
nation by components of the effluent and other substances,
especially volatile ones, holding, acclimation, and culture tanks
should not be in a room in which toxicity tests are conducted,
effluent is stored, test solutions are prepared, or equipment is
cleaned. During holding, acclimation, culture, and testing,
organisms should be shielded from disturbances with curtains
or partitions to prevent unnecessary stress. A timing device
should be used to provide a 16 h light and 8 h dark photope-
riod. A 15 to 30-min transition period (2)when the lights go on
might be desirable to reduce the possibility of organisms being
stressed by large, sudden increases in light intensity. A transi-
tion period when the lights go off might also be desirable (see
Guide E1733).
6.2 Special Requirements—Some organisms require special
conditions during holding, acclimation, and testing. For
example, burrowing mayfly nymphs should be provided a
substrate suitable for burrowing (3);immature stream insects
should be in a current (4); and amphipods, midge larvae, crabs,
shrimp, and bottom-dwelling fish should be provided a silica-
sand substrate. Nylon or stainless steel mesh can also be used
to provide a substrate to which amphipods can cling. Because
cannibalism might occur among many species of decapod
crustaceans, the claws of crabs and crayfish should be banded,
or the individuals should be physically isolated by means of
screened compartments or held individually in test chamber
during testing.
6.3 Construction Materials—Equipment and facilities that
contact effluent samples, test solutions, or any water into which
test organisms will be placed should not contain substances
that can be leached or dissolved by aqueous solutions in
amounts that adversely affect aquatic organisms. In addition,
equipment and facilities that contact effluent samples or test
solutions should be chosen to minimize sorption of effluent
components from water. Glass, Type 316 stainless steel, nylon,
and non-fluorocarbon plastics should be used whenever pos-
sible to minimize dissolution, leaching, and sorption, except
that stainless steel should not be used in tests on metals in salt
water. Concrete and rigid plastics may be used for holding,
acclimation, and culture tanks and in the water supply, but they
should be soaked, preferably in flowing dilution water, for a
week or more before use (5).Cast iron pipe should not be used
with salt water and probably should not be used in a
4
The boldface numbers in parentheses refer to a list of references at the end of
this standard.