4. Selection and Calibration of Monitor Materials
4.1 Selection of Monitor Materials:
4.1.1 Materials selected for temperature monitors shall pos-
sess unique melting temperatures. Since composition, and
particularly the presence of impurities, strongly influence
melting temperature, the fabricated monitor materials shall
consist of either metals of purity 99.9 % or greater or eutectic
alloys such that the measured melting temperature is within
63°C (65 °F) of the recognized melting temperature.
Transmutation-induced changes of the monitor materials sug-
gested in 4.1.2 are not considered significant for fluence
exposures up to 1 × 10
20
n/cm
2
(E > 1 MeV) relative to the
goal of these temperature monitors in flagging deviations from
expected temperatures.
4.1.2 The monitor materials in Table 1 provide temperature
indications in the range of 266 to 327 °C (511 to 621 °F). Other
metals or alloys may be selected for the temperatures of
interest provided the monitor materials meet the technical
requirements of this guide.
4.1.3 The chosen monitor materials shall be carefully evalu-
ated for radiological health hazards.
NOTE 1—It is beyond the scope of this guide to provide safety and
health criteria, and the user is cautioned to seek further guidance.
4.2 Calibration of Monitor Materials—Each lot of monitor
materials shall be calibrated by melting tests to establish the
actual melting temperatures. The melting temperature tests
shall be conducted in accordance with Test Method E794.Ifan
alternate method of calibration is used, the procedure and
equipment must be described, the resultant mean values and
uncertainties must be reported, and traceability to standards
must be declared.
5. Design, Fabrication, and Assembly of Monitor and
Container
5.1 The design of the monitor and its container shall ensure
that the maximum temperature of the surveillance specimens is
determined within 610 °C (618 °F).
5.2 The design shall provide for a minimum of one set of
monitors for each surveillance capsule. Additional sets of
monitors are recommended to characterize the in-service axial
temperature profiles necessary to determine the maximum
temperature of each surveillance specimen.
5.3 The design of the monitor and its container shall ensure
that the monitor will readily sense the environmental tempera-
ture of the surveillance specimens and yet not be subject to any
influences from fabrication or assembly or even post-service
examination. The monitors typically consist of melt wires
positioned adjacent to or among the surveillance specimens.
5.4 The quantity of monitors within each set shall be
adequate to identify any temperature excursion of 10 °C
(18 °F) up to the highest potential temperature, such as 330 °C
(626 °F). It is recommended that monitors be selected to
measure temperature at intervals of 5 to 12 °C (9 to 22 °F). At
least one monitor shall remain intact throughout the service
life; therefore the highest temperature monitor shall possess a
melting temperature greater than the highest anticipated tem-
perature.
5.5 Fabrication and assembly of the monitors and containers
shall protect and maintain the integrity of each temperature
monitor and its ability to respond by melting at the environ-
mental temperature of the surveillance specimens correspond-
ing to the monitors’ melting temperature. The monitors and
containers shall be designed, fabricated, and assembled to
ensure that the monitors melt at a temperature within 63°C
(5 °F) of the environmental temperature of the specimens.
5.6 Identification of each monitor, its material and melting
temperature, and its orientation and location in the surveillance
capsule shall be maintained. Provision for means of verifica-
tion shall be done by design.
6. Post-Irradiation Examination
6.1 Following irradiation, the temperature monitors shall be
examined for evidence of melting to establish the maximum
exposure temperature of the encapsulated surveillance speci-
mens. Precautions should be taken while recovering the moni-
tors from the surveillance capsule and during subsequent
examination.
6.1.1 The monitor design and method of encapsulation shall
be considered in the recovery procedure to ensure that the
monitors are not damaged and that the original identity of
individual monitors and their location is maintained.
6.1.2 Recovery and examination of the monitors should be
performed remotely or with sufficient shielding to protect the
operator from unnecessary radiation exposure.
6.2 Evaluation of the temperature monitors after service for
evidence of melting should be performed using suitable equip-
ment that is dependent on the design of the monitor container
and the examination facility. When visual inspection of the
monitors is possible, such as with periscopes, each monitor
shall be examined and the results recorded. When possible,
photographic records should be made of each monitor or set of
monitors. When visual inspection is not practical or conclusive,
radiography or metallographic examination may be necessary.
Destructive examination should be performed only if further
confirmation of the melting temperature is necessary.
6.3 The monitors shall be evaluated on the following basis:
6.3.1 Unmelted—No evidence of melting of any portion of
the monitor.
6.3.2 Partially Melted—Any evidence of any melting of any
portion of the monitor.
6.3.3 Fully Melted—Evidence that the entire monitor was
subject to melting.
TABLE 1 Monitor Material Melting Temperatures
Monitor Material,
Weight %
Melting Temperature,
°C
Melting Temperature,
°F
Cd–17.4 Zn 266 511
Au–20.0 Sn 280 536
Pb–5.0 Ag–5.0 Sn 292 558
Pb–2.5 Ag 304 579
Pb–1.5 Ag–1.0 Sn 309 588
Pb–1.75 Ag–0.75 Sn 310 590
Cd–1.2 Cu 314 597
Cd 321 610
Pb 327 621
E1214 − 11 (2023)