沙特阿美公司材料系统规范 29-SAMSS-014 消防部门及腰短款上衣 2017 Fire Protection Department Hip Length Jacket

VIP专免
标准之家 2026-09-13 8 123.54KB 7 页 25星币
侵权投诉
Previous Issue: 28 November 2011 Next Planned Update: 17 December 2020
Page 1 of 7
Contact: Bander Saad Al-Ghamdi (ghambs0c) on phone +966-13-8767917
©Saudi Aramco 2017. All rights reserved.
Materials System Specification
29-SAMSS-014 17 December 2017
Fire Protection Department Hip Length Jacket
Document Responsibility: Fire Protection Standards Committee
Contents
1 Scope ............................................................2
2 Conflicts and Deviations..................................2
3 References ....................................................2
4 Material and Manufacturing Requirements .......3
5 Pattern Specifications, Sizes,
and Stock Numbers ........................................6
6 Inspection ......................................................6
Revision Summary................................................6
Attachment A - Shoulder Logo Patch .....................7
Document Responsibility: Fire Protection Standards Committee 29-SAMSS-014
Issue Date: 17 December 2017
Next Planned Update: 17 December 2020 Fire Protection Department Hip Length Jacket
Saudi Aramco: Company General Use
Page 2 of 7
1 Scope
This specification together with the Purchase Order covers the minimum requirements
for hip length outer wear-jacket that is used by Fire Protection Department personnel.
Jackets to this specification are stocked by size under SAP material numbers
1000217504, 1000217505, 1000217506, 1000217508, 1000217543, and 1000217544.
2 Conflicts and Deviations
2.1 Any conflicts between this document and other applicable Mandatory Saudi
Aramco Engineering Requirements (MSAERs) shall be addressed to the
EK&RD Coordinator.
2.2 Any deviation from the requirements herein shall follow internal company
procedure SAEP-302.
2.3 If conflicts or deviations arise between this specification and other Purchase
Order documents not specifically covered as exceptions by the Purchase Order,
the Buyer shall be consulted and a ruling shall be obtained by the manufacturer
in writing before work proceeds. Fire Protection Department reserves the right
to review, test, and reject any manufacturer's uniform jacket before acceptance.
3 References
References listed below are a part of this specification to the extent specified herein and
shall be of the latest edition, addendum, or revision in effect on the date of the Purchase
Order unless otherwise stated.
3.1 Saudi Aramco References
Saudi Aramco Engineering Procedure
SAEP-302 Instructions for Obtaining a Waiver of a Mandatory
Saudi Aramco Engineering Requirement
Saudi Aramco Inspection Requirements
Form 175 Inspection Requirements
3.2 Federal Standards
FED STD 751a Stitches, Seams, and Stitchings
Document Responsibility: Fire Protection Standards Committee 29-SAMSS-014
Issue Date: 17 December 2017
Next Planned Update: 17 December 2020 Fire Protection Department Hip Length Jacket
Saudi Aramco: Company General Use
Page 3 of 7
4 Material and Manufacturing Requirements
4.1 Color
The color will be Paris blue with samples to be provided by Fire Protection
Department.
4.2 Shell Fabric
65% Polyester and 35% combed cotton with high thread count specification
20 x 20 / 98 x 48 tropical weave with durable water repellent finish.
4.3 Body Lining
The lining fabric is a high-count poplin fabric 45 x 45 x 110 x 70 - 58 quilted to
226.8 gm (8 oz) reprocessed acrylic and other fibers - 3.5" x 3.5" quilting.
Additional detachable lining as attached with zip #5, made out of Deluxe fur,
#9010H Blue acrylic fiber with pile length 10 mm, to give cozy and comfortable
warmth. All the edges are securely sewn down.
4.4 Sleeves
The sleeves are secured to the body of the jacket by means of morrow stitch
with a safety stitch to properly strengthen the seam. The same seam is used for
the side closing seams as well.
4.5 Cuffs
Round coat cuff with elasticized fabric grip hidden inside for better protection.
4.6 Collar and Cap
Stand collar with hood attachment. The cap can be hidden inside the collar with
zip closer. Collar length 445 mm (17.5 in), width 90 mm (3.5 in), having strip
with Velcro closer for additional wind protection.
4.7 Pocket
Two large chest patch pockets with pointed flaps 152 mm (6 in) deep, 5.5 inch
wide (140 mm). There is a pencil stitch in the right side of the left pocket
32 mm (1-¼ in) wide, both pockets are to have a 30 mm (1.1 in) box pleat
stitched at top and bottom to prevent spreading. An additional pocket, the same
size as the chest pockets is to be stitched to the inner left side of the Deluxe fur.
Pocket lining is of heavy weight drill. All pocket corners to have heavy duty bar
tacking for extra reinforcement.

标签: #消防 #MS #材料

摘要:

本页面围绕沙特阿美公司材料系统规范 29-SAMSS-014《消防部门及腰短款上衣》(Fire Protection Department Hip Length Jacket)2017版展开,系统介绍 Saudi Aramco Materials System Specification 29-SAMSS-014 对消防部门及腰短款消防夹克的技术要求,包括材料、阻燃与热防护性能、反光标识、尺寸、缝制、标签、检验、测试方法和质量保证等内容,适用于消防装备采购、供应商制造、安全合规、质量检验及工程技

展开>> 收起<<
沙特阿美公司材料系统规范 29-SAMSS-014 消防部门及腰短款上衣 2017 Fire Protection Department Hip Length Jacket.pdf

共7页,预览3页

还剩页未读, 继续阅读

声明:本文档系会员上传,若文档所含内容侵犯了您的版权或隐私,请立即通知,我们立即给予侵权申诉删除!
作者:标准之家 分类:国际标准 价格:25星币 属性:7 页 大小:123.54KB 格式:PDF 时间:2026-09-13

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 7
客服
关注